Main composition and function of binary mixed biber equipment – Wofly Dual gas mixer.
Multi-smart gas free equipment fully automatic gas preparation devices Main components and functions of binary hybrid ratiker equipment.
Main composition and function of binary mixed biber equipment – Wo Fei Dual gas mixer.
1. Gas flow meter: It is the control mechanism of this system, and its actions are directly active. It is a key component of a mixed ratio.
2. Regulated pressure reduction control valve: control pressure and flow, main regulator components of mixed gas pressure.
3. Analyzer: It is the detection mechanism of this device, showing the percentage content in the matching gas. (External)
4. Switching valve: Controlled the penetration of the gas, stop the device operation.
4.1 Gas flow meter: It is the control mechanism of this system, and its actions are directly active. It is a key component of a mixed ratio.
4.2Regulated pressure reduction control valve: control pressure and flow, main regulator components of mixed gas pressure.
4.3 Analyzer: It is the detection mechanism of this device, showing the percentage content in the matching gas. (External)
4.4 Switching valve: Controlled the penetration of the gas, stop the device operation.
4.5 Pressure sensor: detect mixture pressure, and match the valve adjustment pressure, pressure upper and lower limit parameters confirm
4.6 Mixing tank: mixed gas mixing tank, mix all the gas uniform.
4.7 Touch screen: Display real-time flow, gas supply parameters, alarm parameters, etc.
4.7 Electrical portfolio: Control the operating equipment, intuitive display workflow, working status.
Multi-intelligent gas supply equipment fully automatic airfront device 2 yuan package mixed gas supply equipment composition and system design
Multivariate smart gas free equipment fully automatic airway equipment 2 yuan package mixing gas supply unit
The raw material gas is provided in the form of high pressure gas cylinders, and the pressure reduction is pressing to the corresponding entry, the connection is completed, and the equipment intake valve is opened after detecting without leakage. After the system is confirmed, the pressure is started after the pressure is correct, and the pressure of the pressure-reducing regulator valve directly passes through the pressure gauge, and intuitively displays the pressure. When the steel bottle gas is less than the pressure required for the gas, an acoustic warning, a combustible gas pipelines set a single-to-valve to avoid harm to other gas undervoltosis, thereby operating stabilization, and the pressure is constant.
Post time: Mar-26-2022